Holger Thiele1, MD; Divaka Perera2, MD

The Impella device (Abiomed) is a percutaneous transvalvular microaxial flow pump which traverses the aortic valve and pumps blood from the left ventricle (LV) to the ascending aorta. The percutaneous LV Impella systems include the Impella Cardiac Power (CP) and Impella CP SmartAssist, providing up to 3.5 l/min and 4.3 l/min (based on the manufacturer information) using a 14 Fr initial introducer sheath1. This degree of haemodynamic support makes the Impella an attractive adjunct when performing high-risk percutaneous coronary interventions (PCI), which could prevent hypotension or even the development of cardiogenic shock by maintaining cardiac output; it may also facilitate a better outcome in more complex interventions. However, to support such a strategy, evidence derived from randomised clinical trials (RCTs) is needed, since any intervention using large-bore access may also cause harm. The current endorsement for Impella-assisted high-risk PCI is largely based on observational registries, where the decision to utilise the device was driven by a variety of factors beyond carefully defined clinical indications. This article will address the current evidence and clinical practice as well as ongoing RCTs in this setting.

Current randomised evidence for Impella-facilitated non-emergent high-risk PCI

Impella-facilitated non-emergent elective high-risk PCI is increasingly being used to prevent haemodynamic deterioration due to ischaemia that can occur during coronary balloon and stent inflation, calcium modification techniques and unexpected complications such as coronary dissection or branch vessel occlusion. These risks are greatest when the myocardial jeopardy score is high (as in left main or last remaining patent vessel interventions), especially when there is reduced LV function at the outset2.

One of the first RCTs to explore this was the Balloon Pump Assisted Coronary Intervention Study (BCIS-1) including 301 patients, which did not reveal an advantage of intra-aortic balloon pump (IABP)-supported PCI compared with non-supported PCI in high-risk patients3. Subsequently, the PROTECT II Trial randomised 452 patients (of an intended sample size of 654 patients) with either complex 3-vessel coronary artery disease (CAD) or unprotected left main CAD and severely compromised LV ejection fraction (≤35%) to Impella 2.5 versus an IABP-facilitated high-risk PCI4. Importantly, the trial was prematurely terminated by the data safety monitoring board because of its likely futility. The trial used an unusual 10-component primary endpoint combining efficacy and safety endpoints (all-cause death, Q wave or non-Q wave myocardial infarction [MI], stroke or transient ischaemic attack, any repeat revascularisation procedure [PCI or coronary artery bypass graft], need for a cardiac or vascular operation, acute renal insufficiency, severe intraprocedural hypotension requiring therapy, cardiopulmonary resuscitation or ventricular tachycardia requiring cardioversion, aortic insufficiency and angiographic failure of PCI). The intention-to-treat and per-protocol analyses did not show statistically significant differences in major adverse events at 30 days (primary endpoint: 35.1% Impella 2.5 vs 40.1% IABP)4. Interestingly, clinically important individual endpoints such as death and MI were numerically higher in the Impella group. The results of the post hoc per-protocol analysis at 90 days (40.0% vs 51.0%; p=0.023) have led to this being described as a positive trial by some, although this assertion is difficult to justify scientifically, given the neutral effect on the primary outcome of a trial stopped early for futility and its use of an unusual primary endpoint4.

Nevertheless, the Impella 2.5 device received U.S. Food and Drug Administration (FDA) 510(k) clearance for high-risk PCI, and subsequently, other devices (Impella CP, Impella 5.0) have received approval with an expanded indication for cardiogenic shock. Approval of these devices by the FDA and by European regulatory agencies has led to a steadily increasing use of these devices.

Observational data

Currently, there are a multitude of registry data on Impella-assisted PCI, including the following registries: Europella, USpella, cVAD, PREMIER, and CathPCI. The indications for Impella implantation in these registries are often much less stringent than the inclusion criteria of PROTECT II, and many include patients with only mildly reduced or even normal LV ejection fraction2. Based on the retrospective design and selection bias inherent in such series, it is difficult to draw robust conclusions regarding efficacy and, in our view, such results should only be considered hypothesis-generating.

Ongoing randomised clinical trials

There are 2 ongoing RCTs of Impella-assisted high-risk PCI, which both started recruitment in 2021. The Controlled Trial of High-risk Coronary Intervention with Percutaneous Left Ventricular Unloading (CHIP-BCIS3) is an investigatorÂ-initiated trial funded by the National Institute for Health and Care Research in the United Kingdom, which aims to enrol 250 patients undergoing complex PCI in patients with a high myocardial jeopardy score and severely reduced LV ejection fraction. The PROTECT IV Trial is an industry-funded, multicentre RCT comparing Impella-assisted PCI versus standard PCI with or without IABP. The results from both trials (which both have a minimum follow-up duration of 1 year) are expected to be available at the end of 2025 or in 2026. There are important differences and some similarities in the design of these trials, which are summarised in Table 15.

Table 1. Randomised trials of Impella-assisted high-risk PCI.

Clinical trialImpella-Supported PCI in High-Risk Patients With Complex Coronary Artery Disease and Reduced Left Ventricular Function: The PROTECT IV Trial (PROTECT IV)Controlled Trial of High-risk Coronary Intervention with Percutaneous Left Ventricular Unloading (CHIP-BCIS3)
ClinicalTrials.gov identifierNCT04763200NCT05003817
Study start date04/202108/2021
Study completion date03/202606/2025
LocationUSAUK
Sample size1,252250
ConditionCCS, NSTEMI or STEMI ≥24 hours with LVEF ≤40%* undergoing complex PCICCS with 1) extensive CAD (BCIS-Jeopardy score >8)2) LVEF ≤35%3) undergoing complex PCI
Complex PCI definitionComplex PCI defined as ≥1 of:- PCI of distal LM bifurcation- MV PCI with 3-vessel disease- Last remaining patent vessel- 2-vessel PCI of complex lesions- 1-vessel PCI of complex lesion+non-treated CTO or- 1-vessel PCI of complex lesion (in non-infarct vessel) post-STEMIComplex PCI defined as at least one of:1) Unprotected left main intervention in the presence of- an occluded dominant right coronary artery or- a left dominant circulation or- disease involving the entire bifurcation (Medina 1,1,1 or 0,1,1)2) Intended calcium modification (by atherectomy, lithotripsy or laser)- in multiple vessels or- in the left main stem or- in a final patent conduit or- where the anatomical SYNTAX score is ≥323) Target vessel is a CTO with planned retrograde approach
Interventional groupImpella CP or Impella 2.5 placement prior to PCIImpella CP placement prior to PCI
Control groupStandard-of-care PCI with or without an IABPStandard-of-care PCI
Primary outcomeComposite of all-cause death, stroke, durable LVAD/HTx, MI or hospitalisation for cardiovascular causes at 3 years Statistics: classical superiority analysisHierarchical composite:1) death;2) stroke;3) spontaneous MI;4) CV hospitalisation;5) periprocedural MIStatistics: win ratio method
FundingAbiomedNIHR
*if STEMI, LVEF ≤30%. BCIS: British Cardiovascular Intervention Society; CAD: coronary artery disease; CCS: chronic coronary syndrome; CP: Cardiac Power; CTO: chronic total occlusion; CV: cardiovascular; HTx: heart transplant; IABP: intra-aortic balloon pump; LM: left main; LVAD: left ventricular assist device; LVEF: left ventricular ejection fraction; MI: myocardial infarction; MV: multivessel; NIHR: National Institute for Health and Care Research; NSTEMI: non-ST-elevation myocardial infarction; PCI: percutaneous coronary intervention; STEMI: ST-elevation myocardial infarction

Complications

The most common complications of Impella support in elective clinical scenarios are access site bleeding, haemolysis and limb ischaemia due to the large-bore access with an almost mandatory need for therapeutic anticoagulation. The incidence of these complications can be reduced by mandating preprocedural vascular imaging and with the growing experience of operators with closure techniques, but every published series to date has shown this to be an ongoing concern. These possible complications need to be weighed against the possible advantage of haemodynamic support during complex high-risk PCI.

Conclusions

The Impella device can be applied in different clinical scenarios including Impella-facilitated elective high-risk PCI. Besides numerous retrospective studies, there are almost no robust data on the impact of Impella use on outcome and complications, as adequately powered RCTs have not been completed as yet. Thus, Impella use has outpaced the quality of the available data and has been, in part, driven by the disappointing outcomes of other interventions used to support this critically ill population. The physiological rationale and some supporting data have led to substantial and growing use, despite other data suggesting that more caution may be warranted. In the absence of sufficient data from RCTs for the above-mentioned indications, the decision to use the Impella device should be made with caution and based on individual expertise.

The US and European agencies require high-quality clinical data to support approval of all high-risk invasive devices such as the Impella device, as is generally required for new drugs. Approval of these devices should be dependent on demonstrating clinical efficacy and safety in an adequately powered RCT and should not be based on physiological parameters. Additionally, coverage and reimbursement should also be related to clear evidence of benefit. Until such reforms are implemented and given the preponderance of existing evidence, use of the microaxial Impella device in individuals presenting a possible indication of high-risk PCI should be restricted to patients enrolled in RCTs. Whether there is any clinically meaningful benefit in hard endpoints, such as mortality and MI, and if this outweighs the associated harms, can only be addressed by data from such RCTs. In addition, this strategy would prevent a selection bias towards lower-risk patients if not all eligible patients are included. Whilst it is tempting for clinicians to want to be able to provide patients with more advanced therapies for complex high-risk interventional procedures, the interventional community also has a responsibility to ensure that interventions are evidence-based and safe. Therefore, the results of the PROTECT IV and CHIP-BCIS3 trials regarding Impella-facilitated PCI are eagerly awaited.

Conflict of interest statement

The authors have no conflicts of interest to declare.

Volume 20 Number 9
May 10, 2024
Volume 20 Number 9
View full issue


Key metrics

Suggested by Cory

10.4244/EIJ-D-19-00279L Oct 18, 2019
Impella device use in high-risk PCI
Chhabra L et al
free

10.4244/EIJ-D-19-00279R Oct 18, 2019
Reply to the letter to the editor “Impella device use in high-risk PCI”
Khalid N et al
free

State-of-the-Art

10.4244/EIJ-D-24-00386 Feb 3, 2025
Mechanical circulatory support for complex, high-risk percutaneous coronary intervention
Ferro E et al
free

NEW INNOVATION

10.4244/EIJ-D-15-00467 Feb 20, 2018
Design and principle of operation of the HeartMate PHP (percutaneous heart pump)
Van Mieghem NM et al
free

Image – Interventional flashlight

10.4244/EIJ-D-18-00797 Feb 20, 2020
Interventional femoral “crossover” bypass for peripheral ischaemia under cardiocirculatory support with the Impella CP heart pump
Geyer M et al
free
Trending articles
69.996

10.4244/EIJV13I12A217 Dec 8, 2017
Swimming against the tide: insights from the ORBITA trial
Al-Lamee R and Francis D
free
59.65

State-of-the-Art

10.4244/EIJ-D-24-00066 Apr 21, 2025
Management of complications after valvular interventions
Bansal A et al
free
57.6

State-of-the-Art

10.4244/EIJ-D-24-00386 Feb 3, 2025
Mechanical circulatory support for complex, high-risk percutaneous coronary intervention
Ferro E et al
free
38.75

State-of-the-Art

10.4244/EIJ-D-23-00912 Oct 7, 2024
Optical coherence tomography to guide percutaneous coronary intervention
Almajid F et al
free
15.85

State-of-the-Art

10.4244/EIJ-D-23-01050 Jul 15, 2024
Durability of transcatheter aortic valve implantation
Ternacle J et al
free
Chat with Cory
Hello , I'm Cory and I will do my best to answer your questions about this article. Please remember that this is an experimental feature, and that I'm still learning.
What are the key features of the Impella device?
What are the two randomized trials discussed in the content and what are their study populations?
What are the primary outcomes of the PROTECT IV and CHIP-BCIS3 trials?
How does the content discuss the balance between the potential benefits and harms of the Impella device in the absence of sufficient data from randomized trials?
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 7.6
2023 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2024)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2025 Europa Group - All rights reserved