IMAGE IN CARDIOLOGY

DOI: 10.4244/EIJV11I8A193

Use of an Amplatzer® device in a patient with pulmonary sequestration

Jose M. Naranjo Gómez1*, MD; Daniel Valdivia Concha1, MD; Pilar Servent2, MD; Javier Goicolea3, MD

A 28-year-old woman with recurrent episodes of respiratory infections, haemoptysis and an empyema was diagnosed with intralobar pulmonary sequestration (Figure 1A, Moving image 1).

In order to diminish the risk of intraoperative bleeding, we used Amplatzer® devices (St. Jude Medical, St. Paul, MN, USA) as a prior step to surgery (Figure 1B, Figure 1C, Moving image 2, Moving image 3). We decided to use one device for each peripheral branch (Appendix Figure 1) in order to avoid difficulty when sectioning the main vessel. The surgery was carried out successfully without significant bleeding.

Figure 1. Magnetic resonance and angiography imaging. A) Magnetic resonance imaging reconstruction showing blood supply coming from a large-sized aortic dependent artery. B) & C) Angiography imaging before (B) and after (C) placing the Amplatzer devices.

The use of this device has been widely described to occlude cardiac and vascular abnormalities. It has also been used in the management of bronchial pleural fistulae, but this is the first description in a pulmonary sequestration.

Conflict of interest statement

The authors have no conflicts of interest to declare.

Supplementary data

Moving image 1. Preoperative assessment showed blood supply. The drainage was through the pulmonary artery.

Moving image 2. Release of the Amplatzer device.

Moving image 3. End of the embolisation. We did not act on the non-occluded branch because of its size.

Appendix Figure 1. Specimen with both devices inside the two peripheral branches.

Supplementary data

To read the full content of this article, please download the PDF.

Moving image 1. Preoperative assessment showed blood supply. The drainage was through the pulmonary artery.

Moving image 2. Release of the Amplatzer device.

Moving image 3. End of the embolisation. We did not act on the non-occluded branch because of its size.

Volume 11 Number 8
Dec 20, 2015
Volume 11 Number 8
View full issue


Key metrics

Suggested by Cory

IMAGE IN CARDIOLOGY

10.4244/EIJV11I8A192 Dec 20, 2015
Interventional treatment of an aortopulmonary window due to a ruptured suture of an aortic prosthesis
Eißmann M et al
free

10.4244/EIJV15I13A209 Jan 17, 2020
No room at the inn? Pulmonary artery stent implantation and the fate of the bronchus
Thomson J and Krasemann T
free

IMAGE IN CARDIOLOGY

10.4244/EIJV12I9A193 Oct 20, 2016
Large left lung mass: an unexpected finding
Henzel J et al
free
Trending articles
69.996

10.4244/EIJV13I12A217 Dec 8, 2017
Swimming against the tide: insights from the ORBITA trial
Al-Lamee R and Francis D
free
59.65

State-of-the-Art

10.4244/EIJ-D-24-00066 Apr 21, 2025
Management of complications after valvular interventions
Bansal A et al
free
57.6

State-of-the-Art

10.4244/EIJ-D-24-00386 Feb 3, 2025
Mechanical circulatory support for complex, high-risk percutaneous coronary intervention
Ferro E et al
free
38.75

State-of-the-Art

10.4244/EIJ-D-23-00912 Oct 7, 2024
Optical coherence tomography to guide percutaneous coronary intervention
Almajid F et al
free
15.85

State-of-the-Art

10.4244/EIJ-D-23-01050 Jul 15, 2024
Durability of transcatheter aortic valve implantation
Ternacle J et al
free
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 7.6
2023 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2024)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2025 Europa Group - All rights reserved