IMAGE IN CARDIOLOGY

DOI: 10.4244/EIJV11I8A188

Fractional flow reserve in acute coronary syndrome: a word of caution

Abdul Hakeem*, MD; Aatish Garg, MD; Sabha Bhatti, MD; Zubair Ahmed, MD; Barry F. Uretsky, MD

A 42-year-old diabetic male presented with new onset typical cardiac chest pain. There were no ischaemic ECG changes and troponin was 0.13 ng/ml. Angiography showed a 60-70% lesion in the mid left anterior descending (LAD) artery without other lesions. Fractional flow reserve (FFR) evaluation was performed with a baseline pressure gradient of 0.94 (Figure 1) and FFR 0.89 despite increasing iv adenosine infusion from 140 to 180 mcg/kg/min and additional intracoronary adenosine (120, 240 and 360 mcg). Optical coherence tomography (OCT) showed a large thrombus burden in the mid LAD (MLD 1.27 mm, MLA 1.8 mm2) (Appendix Figure 1, Moving image 1). PCI with a drug-eluting stent was performed.

Figure 1. Baseline gradient (Pd/Pa) across mid LAD lesion.

A recent randomised trial suggested a role for FFR-guided management in acute coronary syndrome (ACS). In individual cases, hyperaemic flow may still be adequate to allow a “normal” FFR because other mechanisms have produced ischaemia, such as in the current case where the presence of fresh thrombus produced the ACS with an increased risk of adverse events. Given concerns about FFR measurement in ACS, probably secondary to an inability to achieve maximal hyperaemia, caution is warranted in interpreting FFR in such cases. Intracoronary imaging appears useful in such intermediate ACS cases.

Conflict of interest statement

The authors have no conflicts of interest to declare.

Supplementary data

Moving image 1. OCT imaging run of distal to proximal LAD.

Appendix Figure 1. 70% stenosis in mid LAD on angiography. FFR of LAD 0.89. OCT imaging demonstrating normal-appearing vessel with large lumen (MLA 12.6 mm2, MLD 3.8 mm in the proximal LAD [A], and MLA 8.5 mm2, MLD 3.12 mm in the distal LAD [D]). Large red thrombus in the mid LAD (B & C) with significantly compromised lumen (MLA 1.8 mm2, MLD 1.2 mm).

Supplementary data

To read the full content of this article, please download the PDF.

Moving image 1. OCT imaging run of distal to proximal LAD.

Volume 11 Number 8
Dec 20, 2015
Volume 11 Number 8
View full issue


Key metrics

Suggested by Cory

10.4244/EIJV16I14A204 Feb 19, 2021
Ischaemic risk stratification after deferral of revascularisation on the basis of fractional flow reserve
Echavarria-Pinto M and van de Hoef TP
free
Trending articles
69.996

10.4244/EIJV13I12A217 Dec 8, 2017
Swimming against the tide: insights from the ORBITA trial
Al-Lamee R and Francis D
free
59.65

State-of-the-Art

10.4244/EIJ-D-24-00066 Apr 21, 2025
Management of complications after valvular interventions
Bansal A et al
free
57.6

State-of-the-Art

10.4244/EIJ-D-24-00386 Feb 3, 2025
Mechanical circulatory support for complex, high-risk percutaneous coronary intervention
Ferro E et al
free
38.75

State-of-the-Art

10.4244/EIJ-D-23-00912 Oct 7, 2024
Optical coherence tomography to guide percutaneous coronary intervention
Almajid F et al
free
15.85

State-of-the-Art

10.4244/EIJ-D-23-01050 Jul 15, 2024
Durability of transcatheter aortic valve implantation
Ternacle J et al
free
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 7.6
2023 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2024)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2025 Europa Group - All rights reserved